Profile Mechanical Property
Physical | Test Method | Unit | Value LW/CW | |
E23 | E17 | |||
Tensile Strength | ASTM D-638 | MPa | 300/55 | 200/45 |
Tensile Modulus | ASTM D-638 | GPa | 23/7 | 17/5 |
Compressive Strength | ASTM D-695 | MPa | 250/70 | 200/70 |
Compressive Modulus | ASTM D-695 | GPa | 20/7 | 15/5 |
Flexural Strength | ASTM D-790 | MPa | 300/100 | 200/70 |
Full Section | EN13706-2 | GPa | 23 | 17 |
Interlaminar Shear Strength | ASTM D-2344 | MPa | 25 | 20 |
Density | ASTM D-792 | g/cm3 | 1.72—1.94 | |
Barcol Hardness | ASTM D-495 | >45 | ||
Water Absorption | ASTM D-570 | % max | 1 |
Profile Thermal Property
Thermal | |||
Coefficient of Thermal Expansion | ASTM D-696 | 10-8in/in/℃ | 8 |
Flammiability Classification | UL94 | V0(32) | |
Tunnel Test | E-84 | 20 | |
NBS Smoke Chamber | ASTM E662 | 650 | |
Flammiability Extinguishing | ASTM D-635 | Self extinguishing | |
Fire propagetion | BS476 Part 6 | I<12, i1<6 | |
Surface flame spread | BS476 Part 7 | Class 1/2 | |
Operation temperature | ℃ | +80 to -100 | |
UL Thermal index | Generic | ℃ | 130 |
Profile Electrical Property
Electrical Properties | |||
Item | Test Method | Unit | Value |
Arc Resistance,LW | ASTM D-495 | seconds | 120 |
Dielectric Strength,LW | ASTM D-149 | kV/in | 35 |
Dielectric Strength,PF | ASTM D-149 | Volts/mil | 200 |
Dielectric Constant,PF | ASTM D-150 | @60hz | 5 |
Profile Mechanical Property
Physical | Test Method | Unit | Value LW/CW | |
E23 | E17 | |||
Tensile Strength | ASTM D-638 | MPa | 300/55 | 200/45 |
Tensile Modulus | ASTM D-638 | GPa | 23/7 | 17/5 |
Compressive Strength | ASTM D-695 | MPa | 250/70 | 200/70 |
Compressive Modulus | ASTM D-695 | GPa | 20/7 | 15/5 |
Flexural Strength | ASTM D-790 | MPa | 300/100 | 200/70 |
Full Section | EN13706-2 | GPa | 23 | 17 |
Interlaminar Shear Strength | ASTM D-2344 | MPa | 25 | 20 |
Density | ASTM D-792 | g/cm3 | 1.72—1.94 | |
Barcol Hardness | ASTM D-495 | >45 | ||
Water Absorption | ASTM D-570 | % max | 1 |
Profile Thermal Property
Thermal | |||
Coefficient of Thermal Expansion | ASTM D-696 | 10-8in/in/℃ | 8 |
Flammiability Classification | UL94 | V0(32) | |
Tunnel Test | E-84 | 20 | |
NBS Smoke Chamber | ASTM E662 | 650 | |
Flammiability Extinguishing | ASTM D-635 | Self extinguishing | |
Fire propagetion | BS476 Part 6 | I<12, i1<6 | |
Surface flame spread | BS476 Part 7 | Class 1/2 | |
Operation temperature | ℃ | +80 to -100 | |
UL Thermal index | Generic | ℃ | 130 |
Profile Electrical Property
Electrical Properties | |||
Item | Test Method | Unit | Value |
Arc Resistance,LW | ASTM D-495 | seconds | 120 |
Dielectric Strength,LW | ASTM D-149 | kV/in | 35 |
Dielectric Strength,PF | ASTM D-149 | Volts/mil | 200 |
Dielectric Constant,PF | ASTM D-150 | @60hz | 5 |